products enquiry form
case studies
brochures

Remote Terminal units are configured around the industry standard PC/104 CPU 80x86 core. It hosts a real-time kernel for real-time response in data acquisition and control.

Input / output modules
CMC’s RTU has a variety of digital and analog input/output modules to meet different application needs. These modules are connected to the processor module by a common bus. Field points (I/O points from and to the process) are connected to special signal conditioning modules, which isolate and protect the I/O modules.

Digital input module
The digital input module monitors and detects changes in the state of discrete devices in a process. These inputs can be normally open or normally closed potential-free contacts. The module can both detect and record, with time, the momentary change or can monitor the status of the input contacts. The signal-conditioning module (associated with the digital input module) incorporates galvanic isolation of the field points and has a transient suppressor. This enhances the transient withstanding capability of the RTU.

Digital output module
The digital output module can control the process by changing the status of output contacts. The digital output signal conditioning module provides low power relay contact outputs on an open collector, which can be interfaced to the control circuit of the process.

Analog input module
The analog input module includes a high precision analog to digital converter, sample and hold unit and a CMOS multiplexer. The system executes continuous analog to digital conversions and stores current digital values. Thus the latest data is always available for the host. The AI signal-conditioning module accepts voltage and industry-standard current inputs besides protecting the inputs.

Analog output module
The analog output module provides analog outputs, which can be used to driver a variety of recorders like the strip-chart and x-y, and also to driver continuous control devices using appropriate (voltage or current) analog output signal conditioning module.

Transducer-less power line monitoring modules are also available as part of an RTU. These modules are used in distribution automation applications. They compute the power line parameters: voltage, current, power, frequency etc.

Remote terminal units

Contact
Head - Embedded systems

CMC Centre
Old Mumbai Highway
Gachibowli,
Hyderabad - 500 032
Tel: 91-40-23000401 / 501
Fax:91-40- 23000509
Email: embedded@cmcltd.com



 
Copyright © 2007 CMC Limited, INDIA | Disclaimer | Designed and maintained by The Information Company Pvt Ltd